Terminate call status of DCS bus devices
Contents

1.Description

This module is used in conjunction with the DCS IP gateway (Gira Article No. 2620xx). DCS bus devices which have been called or are waiting for call acceptance can be reset to normal system state, i.e. the optical and acoustic signalling of the active call is reset.

With the optional assignment of the Input 2, DCS bus device groups can be specifically reset.

Application example:
When a door call is triggered, in addition to the connected home stations, the DCS Communicator connected to the DCS IP gateway also signals the active door call. If the door is opened outside the door communication in this status, the called DCS bus devices can be reset to normal mode via the HomeServer.
Important
The module requires the firmware version of the DCS IP gateway 1.11 or higher!

2.Inputs

No.NameInitialisationDescription
1Trigger0
Each time a 1-telegram is received at this input, a telegram is generated for the DCS IP gateway and is output at the output.
2DCS bus devices3
Optional specification of a group of DCS bus devices.
The following values are possible:
1 = Terminate call status of all DCS Communicators
2 = Terminate call status of all other DCS bus devices
3 = Terminate call status of all DCS bus devices (also DCS Communicator)

The input is initialised to value 3.
Important
For call participation of the DCS IP gateway, the sole termination of the call status of DCS bus devices (default value 2) is not possible! In this case, the call status of a third DCS bus device called at the same time is notchanged.

3.Outputs

No.NameInitialisationSBCDescription
1Door communication Send""s
(14 bytes – Text)
Here the internal communication object Door communication Send is assigned by the DCS IP gateway.
2Error output0s
The output can be routed to the outside as a diagnostic output if necessary or during start-up in order to obtain information about possible errors.
Values in the value range of 0 to 1 are sent.
0 = An error has not occurred.
1 = The default values must be checked.
s = send, sbc = send by change

4.Other

Recalculation during start:No
Module is retentive:Yes
Internal designation:16951
Category:Door communication\Send

5.Similar functions

Receive
Receive\Evaluate code from code keypad
Send
Additional modules