Door station voice message
Contents

1.Description

This module is used in conjunction with the DCS IP gateway (Gira Order No. 2620 ..).
The module enables a predefined voice message (which is available as a ".wav" file) to be played back on a door station via the Gira HomeServer.
A maximum of 5 voice messages can be played back sequentially on the door station.

The activation of the EIB alarm control unit is also acknowledged using a voice message on the door station of the Gira door communication.
Note
The module requires the firmware version of the DCS IP gateway 3 or higher!

2.Inputs

No.NameInitialisationDescription
1Trigger Door station voice message0
(1 bit)
When a 1-telegram is received, a telegram is generated to retrieve a voice message at the DCS IP gateway.
2ID - 1st Voice message0
(0-255)
Unique ID of the voice message which should be called up first.
Voice messages that are not used are assigned 0.
3ID - 2nd Voice message0
(0-255)
Unique ID of the voice message which should be called up at 2nd position.
Voice messages that are not used are assigned 0.
4ID - 3rd Voice message0
(0-255)
Unique ID of the voice message which should be called up at 3rd position.
Voice messages that are not used are assigned 0.
5ID - 4th Voice message0
(0-255)
Unique ID of the voice message which should be called up at 4th position.
Voice messages that are not used are assigned 0.
6ID - 5th Voice message0
(0-255)
Unique ID of the voice message which should be called up at 5th position.
Voice messages that are not used are assigned 0.
7Target address""
(14-byte text)
Specification of a target address from where the voice message should be issued.
The target address must have the following format here:
Example: 0xABCD07 or 0x42A305

3.Outputs

No.NameInitialisationSBCDescription
1Door communication Send""s
(14 bytes – Text)
Here the internal communication object Door communication Send is assigned by the DCS IP gateway.
2Error output0s
The output can be routed to the outside as a diagnostic output if necessary or during start-up in order to obtain information about possible errors.
Values in the value range of 0 to 1 are sent.
0 = An error has not occurred.
1 = Check the default values for the target address.
s = send, sbc = send by change

4.Other

Recalculation during start:No
Module is retentive:Yes
Internal designation:16940
Category:Door communication\Send

5.Similar functions

Receive
Receive\Evaluate code from code keypad
Send
Additional modules