1.Description
The module is used to determine basic parameters of the sending door communication devices in conjunction with the Gira DCS-IP gateway (Article No. 2260xx).
The following information must be output in dependence on the sender:
The following information must be output in dependence on the sender:
- Bus address
- Target address (with specific TC bus telegrams)
- Sender type
- Top unit number
- Button number
- Keyless In device type
- Index number
- Button event DCS Communicator, home station or TC gateway
- Button event – Number of the triggering DCS Communicator
If a device does not offer a certain parameter (e.g. target address), then an empty string is sent to delete the display of the previous value.
The basic parameters are required for the parameterisation of the logic nodes in conjunction with the Gira DCS IP gateway.
The module requires the firmware version of the DCS IP gateway 1.11 or higher!
The basic parameters are required for the parameterisation of the logic nodes in conjunction with the Gira DCS IP gateway.
The module requires the firmware version of the DCS IP gateway 1.11 or higher!
2.Inputs
No. | Name | Initialisation | Description |
---|---|---|---|
1 | Door communication Receive | "" | (14 bytes – Text) Here the internal communication object Door communication Receive is assigned by the DCS IP gateway. |
3.Outputs
No. | Name | Initialisation | SBC | Description |
---|---|---|---|---|
1 | Bus address | "" | s | When a telegram is received from the DCS IP gateway, the output sends the bus address as a 14-byte text of the door communication device which has sent the telegram. Example: 0x000011 |
2 | Target address | "" | s | When a telegram is received from the DCS IP gateway, the output sends the bus address as a 14-byte text of the door communication device which has sent the telegram. Example: 0x000011 |
3 | Top unit | "" | s | 14-byte text output of the numeric value in the range from 0 to 31 |
4 | Button number | "" | s | 14-byte text output of the numeric value in the range from 0 to 127 |
5 | Sender type | "" | s | 14-byte text output of the device type from which the TC bus telegram was sent. 160 = Door station 161 = Living area intercom 162 = Living area intercom receiver 163 = Bus control device 164 = Switching actuator 165 = TC gateway 166 = Additional gong/Bus chiming mechanism 167 = Button interface 168 = DCS IP gateway |
6 | Keyless In device type | "" | s | 14-byte text output of the numeric value in the range 0 to 7 1 = Transponder reader 2 = Fingerprint reader 3 = Code keypad |
7 | Index number | "" | s | 14-byte text output of the numeric value in the range from 0 to 255 Examples: Finger 17 Value 252: Sabotage contact of code keypad Value 253: F button pressed Value 254: invalid index detected Value 255: old Keyless In firmware |
8 | Button event | "" | s | 14-byte text output of the numeric value in the range from 0 to 255 Value 1: Light button pressed Value 2: Door opener button pressed Value 16: End of call Value 17: Call acceptance |
9 | Button event - Number of the triggering DCS Communicator | "" | s | 14-byte text output of the numeric value in the range from 1 to 255 Number of the DCS Communicator which triggered the button event. |
s = send, sbc = send by change
4.Other
Recalculation during start: | No |
---|---|
Module is retentive: | No |
Internal designation: | 16930 |
Category: | Door communication\Additional modules |
5.Similar functions
Receive
Switching action
Floor call
Internal call
Door call (incl. bell symbol on code keypad)
Switching action Keyless In
Door opener command
Door opener command of device with KeyLess In
Light function
Evaluation Sabotage KeyLessIn
Evaluate status automatic door opener DCS Communicator
Button event DCS Communicator
Button event home station/TC gateway
Evaluate voice message door station
Evaluate status of forwarding
Response - Evaluate status of JPEG image call
Evaluation of sabotage control device
Floor call
Internal call
Door call (incl. bell symbol on code keypad)
Switching action Keyless In
Door opener command
Door opener command of device with KeyLess In
Light function
Evaluation Sabotage KeyLessIn
Evaluate status automatic door opener DCS Communicator
Button event DCS Communicator
Button event home station/TC gateway
Evaluate voice message door station
Evaluate status of forwarding
Response - Evaluate status of JPEG image call
Evaluation of sabotage control device
Receive\Evaluate code from code keypad
Universal filter function with code specification as text
Universal filter function with code specification as value
Universal filter function with code specification as value
Send
Light function
Switching action
Query/set automatic door opener DCS Client
Door station voice message
Query/set forwarding
Terminate call status of DCS bus devices
Switching action
Query/set automatic door opener DCS Client
Door station voice message
Query/set forwarding
Terminate call status of DCS bus devices
Additional modules