Query/set forwarding
Contents

1.Description

This module is used in conjunction with the DCS IP gateway (Gira Order No. 2620 ..).

The Gira HomeServer allows a forwarding to be set or the current status of the forwarding to be read out.

Inputs 1 to 3 are used as trigger inputs and allow the forwarding to be activated, deactivated or its current status to be read out.
The forwarding ID whose status should be changed or read out is specified via Input 4.
Note
The forwarding ID can be read from the HomeServer cheat sheet of the DCS IP gateway for the desired call button.
The module requires the firmware version of the DCS IP gateway 3 or higher!

The evaluation of a status query or state change is via the logic node "Evaluate forwarding status feedback" in the Door communication\Receive folder.

2.Inputs

No.NameInitialisationDescription
1Trigger: Activate forwarding0
Each time a telegram is received with an input value greater than zero at this input, a telegram is generated to switch on forwarding for the DCS IP gateway and is output at the output.
2Trigger: Deactivate forwarding0
Each time a telegram is received with an input value greater than zero at this input, a telegram is generated to switch off forwarding for the DCS IP gateway and is output at the output.
3Trigger: Query forwarding status0
Each time a telegram is received with an input value greater than zero at this input, a telegram is generated to query the status of the forwarding setting for the DCS IP gateway and is output at the output.
4Number of forwarding ID0
Specification of a forwarding ID for which forwarding behaviour is set or queried.
The input is pre-initialised with the value 0, which means a value in the value range from 1 to 255 must be parameterised!
Note
The forwarding ID can be read from the HomeServer cheat sheet of the DCS IP gateway for the desired call button.

3.Outputs

No.NameInitialisationSBCDescription
1Door communication Send""s
(14 bytes – Text)
Here the internal communication object Door communication Send is assigned by the DCS IP gateway.
2Error output0s
The output can be routed to the outside as a diagnostic output if necessary or during start-up in order to obtain information about possible errors.
Values in the value range of 0 to 1 are sent.
0 = An error has not occurred.
1 = The default values for the number of the forwarding ID must be checked.
s = send, sbc = send by change

4.Other

Recalculation during start:No
Module is retentive:Yes
Internal designation:16942
Category:Door communication\Send