Evaluate status of automatic door opener DCS Communicator
Contents

1.Description

This module is used in conjunction with the DCS IP gateway (Gira Order No. 2620 ..). It evaluates whether a changeover/status query of the automatic door opener by the Gira HomeServer (logic node: Query/set automatic door opener DCS Client) is confirmed by the DCS IP gateway.

If successful, the module at Output 1 sends a 1 telegram. In the case of an error, Output 1 sends a 0 telegram.
In addition, the cause of the error is output at the error output.

2.Inputs

No.NameInitialisationDescription
1Door communication Receive""
(14 bytes – Text)
Here the internal communication object Door communication Receive is assigned by the DCS IP gateway.
2DCS Communicator number0
Specification of a number of the DCS Communicator to which filtering is to be applied.
The input is pre-initialised with the value 0, i.e., no telegram is evaluated.
A value in the value range of 1 to 255 must be parameterised.
Note
The number of the DCS Communicator (value range 1-255) is assigned in the configuration level of the DCS IP gateway.
3Status-1
Specification of a status on which the incoming telegram should be filtered.
0 = automatic door opener for the selected number of the DCS Communicator is deactivated.
1 = automatic door opener for the selected number of the DCS Communicator is activated.

3.Outputs

No.NameInitialisationSBCDescription
1Action successful0s
The changeover request triggered via the Gira HomeServer logic node or the status query of the automatic door opener is confirmed with a 1-telegram if successful. If the changeover or the status query was not successful, a 0-telegram is sent.
2DCS Communicator number0s
Number of the DCS Communicator, the automatic door opening changeover or the status feedback.
(Value range 0–255)
3Current status-1s
In the case of successful changeover/status query, the output sends the current status.
0 = automatic door opener for the selected number of the DCS Communicator is deactivated.
1 = automatic door opener for the selected number of the DCS Communicator is activated.
Note
If the changeover request or the status query was not successful, this output does not send a telegram.
4Error output0s
The output can be routed to the outside as a diagnostic output if necessary or during start-up in order to obtain information about possible errors.
Values in the value range of 0 to 6 are sent.

0 = An error has not occurred.
1 = The automatic door opener is not enabled for the DCS Communicator.
2 = The DCS Communicator is offline.
3 = The DCS Communicator does not respond.
4 = Telegram received with a different number of the DCS Communicator.
5 = A telegram was received with a different structure.
6 = The default values must be checked
s = send, sbc = send by change

4.Other

Recalculation during start:No
Module is retentive:No
Internal designation:16934
Category:Door communication\Receive

5.Similar functions

Receive
Receive\Evaluate code from code keypad
Send