Query/set automatic door opener DCS Client
Contents

1.Description

This module is used in conjunction with the DCS IP gateway (Gira Order No. 2620 ..). The Gira HomeServer allows the automatic door opener to be set for a DCS Communicator or the current status of the automatic door opener to be read out.

Inputs 1 to 3 are used as trigger inputs and allow the status of the automatic door opener to be activated, deactivated or its current status to be read out. The logic ID of the DCS Communicator, the status of which is to be changed or read out, is specified over Input 4.

Example:
In a medical centre with several doctors practices and common door communication with DCS IP gateway, the automatic door opener is automated during opening hours of the practices via the universal timer of the HomeServer and visually displayed in the Gira interface.

The module requires the firmware version of the DCS IP gateway xyz or higher!

The evaluation of a status query or state change is via the logic node "Evaluate status automatic door opener DCS Communicator" in the Door communication\Receive folder.

2.Inputs

No.NameInitialisationDescription
1Trigger Switch on automatic door opener0
Each time a telegram is received with an input value greater than zero at this input, a telegram is generated to switch on the automatic door opener for the DCS IP gateway and is output at the output.
2Trigger Switch off automatic door opener0
Each time a telegram with an input value greater than zero is received at this input, a telegram is generated to switch off the automatic door opener for the DCS IP gateway and is output at the output.
3Trigger Query automatic door opener0
Each time a telegram with an input value greater than zero is received at this input, a telegram is generated to query the status of the automatic door opener for the DCS IP gateway and is output at the output.
4DCS Communicator number0
Specification of a number of the DCS Communicator for which the automatic door opener should be set or queried.
The input is pre-initialised with the value 0, which means a value in the value range from 1 to 255 must be parameterised!
Note
The number for the DCS Communicator (value range 1-255) is assigned in the configuration level of the DCS IP gateway.

3.Outputs

No.NameInitialisationSBCDescription
1Door communication Send""s
(14 bytes – Text)
Here the internal communication object Door communication Send is assigned by the DCS IP gateway.
2Error output0s
The output can be routed to the outside as a diagnostic output if necessary or during start-up in order to obtain information about possible errors.
Values in the value range of 0 to 1 are sent.
0 = An error has not occurred.
1 = The default values for the number of the DCS Communicator must be checked.
s = send, sbc = send by change

4.Other

Recalculation during start:No
Module is retentive:Yes
Internal designation:16932
Category:Door communication\Send

5.Similar functions

Receive
Receive\Evaluate code from code keypad
Send
Additional modules