1.Description
This module is used in conjunction with the DCS IP gateway (Gira Order No. 2620 ..). The Gira HomeServer allows the automatic door opener to be set for a DCS Communicator or the current status of the automatic door opener to be read out.
Inputs 1 to 3 are used as trigger inputs and allow the status of the automatic door opener to be activated, deactivated or its current status to be read out. The logic ID of the DCS Communicator, the status of which is to be changed or read out, is specified over Input 4.
Example:
In a medical centre with several doctors practices and common door communication with DCS IP gateway, the automatic door opener is automated during opening hours of the practices via the universal timer of the HomeServer and visually displayed in the Gira interface.
The module requires the firmware version of the DCS IP gateway xyz or higher!
The evaluation of a status query or state change is via the logic node "Evaluate status automatic door opener DCS Communicator" in the Door communication\Receive folder.
Inputs 1 to 3 are used as trigger inputs and allow the status of the automatic door opener to be activated, deactivated or its current status to be read out. The logic ID of the DCS Communicator, the status of which is to be changed or read out, is specified over Input 4.
Example:
In a medical centre with several doctors practices and common door communication with DCS IP gateway, the automatic door opener is automated during opening hours of the practices via the universal timer of the HomeServer and visually displayed in the Gira interface.
The module requires the firmware version of the DCS IP gateway xyz or higher!
The evaluation of a status query or state change is via the logic node "Evaluate status automatic door opener DCS Communicator" in the Door communication\Receive folder.
2.Inputs
No. | Name | Initialisation | Description |
---|---|---|---|
1 | Trigger Switch on automatic door opener | 0 | Each time a telegram is received with an input value greater than zero at this input, a telegram is generated to switch on the automatic door opener for the DCS IP gateway and is output at the output. |
2 | Trigger Switch off automatic door opener | 0 | Each time a telegram with an input value greater than zero is received at this input, a telegram is generated to switch off the automatic door opener for the DCS IP gateway and is output at the output. |
3 | Trigger Query automatic door opener | 0 | Each time a telegram with an input value greater than zero is received at this input, a telegram is generated to query the status of the automatic door opener for the DCS IP gateway and is output at the output. |
4 | DCS Communicator number | 0 | Specification of a number of the DCS Communicator for which the automatic door opener should be set or queried. The input is pre-initialised with the value 0, which means a value in the value range from 1 to 255 must be parameterised! Note The number for the DCS Communicator (value range 1-255) is assigned in the configuration level of the DCS IP gateway. |
3.Outputs
No. | Name | Initialisation | SBC | Description |
---|---|---|---|---|
1 | Door communication Send | "" | s | (14 bytes – Text) Here the internal communication object Door communication Send is assigned by the DCS IP gateway. |
2 | Error output | 0 | s | The output can be routed to the outside as a diagnostic output if necessary or during start-up in order to obtain information about possible errors. Values in the value range of 0 to 1 are sent. 0 = An error has not occurred. 1 = The default values for the number of the DCS Communicator must be checked. |
s = send, sbc = send by change
4.Other
Recalculation during start: | No |
---|---|
Module is retentive: | Yes |
Internal designation: | 16932 |
Category: | Door communication\Send |
5.Similar functions
Receive
Switching action
Floor call
Internal call
Door call (incl. bell symbol on code keypad)
Switching action Keyless In
Door opener command
Door opener command of device with KeyLess In
Light function
Evaluation Sabotage KeyLessIn
Evaluate status automatic door opener DCS Communicator
Button event DCS Communicator
Button event home station/TC gateway
Evaluate voice message door station
Evaluate status of forwarding
Response - Evaluate status of JPEG image call
Evaluation of sabotage control device
Floor call
Internal call
Door call (incl. bell symbol on code keypad)
Switching action Keyless In
Door opener command
Door opener command of device with KeyLess In
Light function
Evaluation Sabotage KeyLessIn
Evaluate status automatic door opener DCS Communicator
Button event DCS Communicator
Button event home station/TC gateway
Evaluate voice message door station
Evaluate status of forwarding
Response - Evaluate status of JPEG image call
Evaluation of sabotage control device
Receive\Evaluate code from code keypad
Universal filter function with code specification as text
Universal filter function with code specification as value
Universal filter function with code specification as value
Send
Light function
Switching action
Door station voice message
Query/set forwarding
Terminate call status of DCS bus devices
Switching action
Door station voice message
Query/set forwarding
Terminate call status of DCS bus devices
Additional modules