Storm shutter control
Contents

1.Description

The module controls the opening or closing of storm shutters in the required order. Close: First Leaf 1 is closed; the movement time is specified with Input 3. Then Leaf 2 is closed; its movement time is specified with Input 4. Open: First Leaf 2 is opened, then Leaf 1. During an ongoing closing or opening process, telegrams at Input 1 have no effect. An ongoing process can be interrupted at any time with the short-term object (Input 2).

2.Inputs

No.NameInitialisationDescription
1Input 1 (1 bit; 0=open/1=close)0
Long-term (1 bit; 1=close, 0=open)
2Stop/Short-term (1 bit)0
Short-term (1 bit)
3Movement time of leaf 1 (sec.)0
Measured movement time for Leaf 1 in seconds
4Movement time of leaf 2 (sec.)0
Measured movement time for Leaf 2 in seconds

3.Outputs

No.NameInitialisationSBCDescription
1Leaf 1 (long-term)0s
Long-term object (1 bit) Leaf 1
2Leaf 1 (short-term)0s
Short-term object (1 bit) Leaf 1
3Leaf 2 (long-term)0s
Long-term object (1 bit) Leaf 2
4Leaf 2 (short-term)0s
Short-term object (1 bit) Leaf 2
s = send, sbc = send by change

4.Other

Recalculation during start:No
Module is retentive:Yes
Internal designation:19015
Category:Blind-shutter-partition wall

5.Similar functions

Position display for shutters (with additional positioning input)
Room divider controller